mirror of
https://gitee.com/callmer/pve_toss_notes.git
synced 2026-08-31 22:12:51 +08:00
update 3.硬件BIOS配置.md.
This commit is contained in:
+28
-3
@@ -1,9 +1,34 @@
|
||||
## 1.虚拟化功能确认
|
||||
|
||||
进入“Advanced”菜单的子菜单“CPU Configuration”:
|
||||
进入 `Advanced` 菜单的子菜单 `CPU Configuration` :
|
||||
|
||||

|
||||
|
||||
检查“Intel (VMX) Virtualization Technology”选项为“Enable”:
|
||||
检查 `Intel (VMX) Virtualization Technology` 选项为 `Enabled` :
|
||||
|
||||

|
||||

|
||||
|
||||
## 2.CPU功耗确认
|
||||
|
||||
进入 `Advanced` 菜单的子菜单 `Power & Performance` :
|
||||
|
||||

|
||||
|
||||
进入 `CPU - Power Management Control` :
|
||||
|
||||

|
||||
|
||||
确认 `C states` 为 `Enabled` 状态:
|
||||
|
||||

|
||||
|
||||
再进入 `HDC Control` 菜单的子菜单 `View/Configure Turbo Options` :
|
||||
|
||||

|
||||
|
||||
确认以下内容
|
||||
- `Power Limit 1 Override` 参数:`Enabled`
|
||||
- `Power Limit 1` 参数:`15000`
|
||||
- `Power Limit 1 Time Window` 参数:为最大 `128`
|
||||
|
||||

|
||||
|
||||