Updated the readme to differentiate between identifier tag and the compilation command. Added also a line for flashing using GUI.
5.0 KiB
ONT-S207CW-62TS-SE / Binardat 2G06-04210GSM / Binardat 2G06-04210GS
Overview
ONT-S207CW-62TS-SE, Binardat 2G06-04210GSM (managed), and Binardat 2G06-04210GS (unmanaged) are switches with identical hardware:
- CPU: RTL8372N (confirmed via serial: "Detecting CPU: RTL8372N")
- Flash: GD25Q128E (16MB)
- Ports: 4x 2.5G RJ45 + 2x 10G SFP+
- Console: 115200 baud (RTLPlayground firmware) / 9600 baud (stock firmware)
Note: These devices are RTL8372N-based with LAN ports mounted upside-down on the PCB, requiring a custom configuration. The MACHINE_ONT_S207CW_62TS_SE definition uses a custom configuration with:
- Corrected port mapping (physical ports 1-4 = RJ45, 5-6 = SFP)
- Optimized LED sets for different port wiring (RJ45 Ports 1-2 have reversed LED wiring)
- Custom LED mux configuration
Device Photos
Binardat 2G06-04210GSM
Photos courtesy of andreas5232 from emesix/ONT-S207CW-62TS-SE#1
Hardware Specification
| Feature | Value |
|---|---|
| CPU | RTL8372N |
| Flash | GD25Q128E (16MB) |
| RAM | Integrated in RTL8372N |
| RJ45 Ports | 4x 2.5GBase-T (Ports 1-4) |
| SFP+ Ports | 2x 10G (Ports 5-6) |
| Console | UART (115200 baud for RTLPlayground, 9600 baud for stock) |
| Stock Web UI IP | 192.168.2.1 |
| Loader Mode IP | 192.168.10.247 |
Port Layout
┌─────────────────────────────────────────────┐
│ ┌─────┐ ┌─────┐ ┌─────┐ ┌─────┐ ┌─────┐ ┌─────┐ │
│ │RJ45 │ │RJ45 │ │RJ45 │ │RJ45 │ │SFP+ │ │SFP+ │ │
│ │ 1 │ │ 2 │ │ 3 │ │ 4 │ │ 5 │ │ 6 │ │
│ └─────┘ └─────┘ └─────┘ └─────┘ └─────┘ └─────┘ │
│ │
│ [System LEDs] │
└─────────────────────────────────────────────┘
LED Behavior
RJ45 Ports (Physical 1-4)
| LED Color | Speed |
|---|---|
| Green | 2.5G |
| Orange | 1G / 100M / 10M |
| Off | No link |
SFP+ Ports (Physical 5-6)
| LED Color | Speed |
|---|---|
| Green | 10G |
| Orange | 2.5G / 1G |
| Off | No link / No SFP module |
Port to Logical Mapping
Custom mapping for ONT-S207CW-62TS-SE:
| Physical Port | Logical Port | Type | LED Set |
|---|---|---|---|
| 1 | 7 | RJ45 | 2 |
| 2 | 6 | RJ45 | 2 |
| 3 | 5 | RJ45 | 0 |
| 4 | 4 | RJ45 | 0 |
| 5 | 3 | SFP+ (SDS0) | 3 |
| 6 | 8 | SFP+ (SDS1) | 3 |
Note: Ports 1-2 (RJ45) have reversed LED wiring and use LED-Set 2. SFP Ports 5-6 use LED-Set 3 to account for wiring differences.
Flashing Instructions
See the README.md for general flashing instructions.
For compilation, use command make MACHINE=ONT_S207CW_62TS_SE to specify the machine.
If you are using managed version of the switch, you can then also compile the installer and flash using GUI - run command cd installer and finally make.
Stock Firmware Information
| Property | Value |
|---|---|
| Default IP | 192.168.2.1 (ONT) / 192.168.10.247 (Loader Mode) |
| Default Login | admin/admin (may vary by OEM) |
| Console Baud | 9600 (stock) / 115200 (RTLPlayground) |
| CPU String | "RTL8372N" |
| Loader Mode IP | 192.168.10.247 |
Configuration Details
- CPU: RTL8372N
- SFP: SDS0 on logical port 3 (GPIO37), SDS1 on logical port 8 (GPIO38)
- Port Mapping: Physical 1-4 → Logical 7-4, Physical 5-6 → Logical 3,8
- LED Wiring: RJ45 Ports 1-2 and SFP Port 6 have reversed LED pins (orange/green swapped)
- LED Sets: Set 0 for RJ45 Ports 3-4, Set 1 unused, Set 2 for RJ45 Ports 1-2, Set 3 for SFP Ports 5-6
Notes
- ONT-S207CW-62TS-SE, Binardat 2G06-04210GSM (managed), and Binardat 2G06-04210GS (unmanaged) are RTL8372N-based with LAN ports mounted upside-down on the PCB
- Web UI shows correct physical port order (1-2-3-4 for RJ45, 5-6 for SFP)
- Loader Mode always remains accessible at
192.168.10.247for recovery - Serial console: 9600 baud (stock) → 115200 baud (RTLPlayground)
References
- GitHub Issue: emesix/ONT-S207CW-62TS-SE#1 - Original photos and discussion
- PR: logicog/RTLPlayground#465 - Feedback and improvements