Supported Hardware
The following devices have been tested and are fully working:
| Brand | Type | Managed | PCB | Flash | Ports |
|---|---|---|---|---|---|
| Ampcom | WAM902-SWTG018AS | No | SWTG018AS-A V2.0 | 8 + 1 | |
| Davuaz | Da-K6501W | No | PCB-K0501W-V2.0 | 5 + 1 | |
| FOXNEO | FNS-1200P | No | PCB-K0402W-U13-V2.0 | 2M | 4 + 2 |
| Hisource | Hi-K0402WS | No | PCB-K0402WS-V3.0 | 4 + 2 | |
| Hisource | Hi-K0801WS | No | PCB-KO801W-V2.0 | 8 + 1 | |
| hongyavision | LG-SG5T1 | No | PCB-SWTG024AS-V2.0_16895 | 0.5M | 5 + 1 |
| Horaco | HC-SWTGW215AS | Yes | SWTG024AS-A-V2.0.1_19650 5C 1SFP | ? | 5 + 1 |
| Horaco | HC-SWTGW218AS | Yes | SWTG018AS-A V2.0 | 8 + 1 | |
| Horaco | ZX310S-4T2XH | Yes | PCB-SL310S-4T1T1X-V1.0.1-24107 | 2M | 5 + 1 |
| Horaco | ZX310S-4T2XT | Yes | PCB-SL310S-4T2XT-V1.0.0-22273 | 2M | 6 |
| Horaco | ZX-SG4T2 | No | SWTG024AS-A-V2.0.1_19650_4C_2SFP | 0.5M | 4 + 2 |
| Horaco | ZX-SWTG124AS | Yes | SWTG024AS-v2.0 | 4 + 2 | |
| Keeplink | KP-9000-6XH-X2 / KP-9000-6XHML-X2 | No/Yes | 2M-PCB43-V1.2 / V2.1 | 4 + 2 | |
| keepLINK | KP-9000-9XHML-X | Yes | 2M-PCB23-V2.2 | 2M | 8 + 1 |
| keepLINK | KP-9000-9XHML-X | Yes | 2M-PCB23-V3.1 | 2M | 8 + 1 |
| LIANGUO | SWTG024AS | No | SWTG024AS-v2.0-17452 | 0.5M | 4 + 2 |
| Lianguo | ZX-SWTGW215AS | Yes | PCB-SWTG115AS-V2.0 | 2M | 5 + 1 |
| Mokerlink | 2G040210GSM | Yes | 2M-PCB43-V1.1 | 4 + 2 | |
| Mokerlink | ZX-SWTGW218AS | Yes | SWTG118AS-V2.0-16029 | 2M | 8 + 1 |
| Ruiying | RY-4GT-2SX | No | FG-4GT-2SX_V2.0 | 4M | 4 + 2 |
| Sodola | SL-SWTG124AS-D | Yes | SWTG024AS-v2.0-17452 | 2M | 4 + 2 |
| Steamemo | IG204-V1 | No | PB-2131 | 4 + 2 | |
| TrendNet | TEG-S562 | No | TEG-S563/EU H/W: V1.0R | 2M | 4 + 2 |
| Xikestore | SKS3200M-4GPY2XF | Yes | SWTG024AS-v1.0 | 4 + 2 | |
| XikeStor | SKS3200-8E1X | Yes | SWTG118AS-V2.1-17462 | 2M | 8 + 1 |
| Ztyuav | Z-QWYT0402 | No | PCB-K0402WS-V3.0 | 4 + 2 |
For KP-9000-6XH-X2 / KP-9000-6XHML-X2 / Mokerlink 2G040210GSM devices, select the machine target by PCB revision. The ML/non-ML or managed/unmanaged label alone does not identify the wiring.
Other device based on RTL8272/3 that may work are described here: Up-N-Atoms 2.5 GBit RTL Switch hacking guide
Many of the RTL8272/3 devices come in versions with PoE support. The RTLPlayground usually also works on these, however, no support for configuring PoE is provided, simply because these devices usually just provide PoE on all ports without further configuration possibilitites.
The following forum also discusses this type of switches: ServeTheHome
There are also 16-port unmanaged devices with RTL8272 SoCs, however these devices do not have serial consoles and use 4 independent RTL8272 SoCs. No central control is provided by RTLPlayground, even if it has been successfully demonstrated to install RTLPlayground to individual SoCs.