gcc flags the else whose only statement is dbg_string(), because that macro
expands to nothing unless DEBUG is on, leaving the branch with an empty body.
The line is older than this branch; the bench is simply the first thing that
compiles httpd.c with a host compiler and -Wall -Wextra.
Turn warnings into errors in the test Makefile too, so the next one is caught
where it appears instead of scrolling past. It is the only warning the four
test binaries produce, so nothing else has to change.
The replay takes a line of at most 126 bytes, so a longer one is skipped
on boot. Neither the upload path nor the editor looked at line length,
so the file the user saved was not the configuration the switch would
come up with.
Reject such a body in config_take(), before the sector is erased, which
the upload path already maps to 400. The editor points at the offending
line and its length, and measures it in bytes rather than characters, so
a name written in a non-ASCII script is counted the way the switch
counts it.
execute_config() replays the saved configuration line by line into
cmd_buffer. A line that does not fit, or one cmd_tokenize() rejects,
ended the replay right there: everything below it was silently left
unapplied, while the file itself and the editor showing it stayed
complete. On a switch here, a 130-byte line placed after the last real
setting was enough to lose every line that followed it on the next boot.
Report the offending line and carry on with the next one. The skip flag
lives across the flash page refill, so a long line that crosses a page
boundary is not resumed halfway and run as a truncated command.
Drives the unmodified httpd.c and uip.c through a handshake and a GET
from a client that moves its receive window, and compares the bytes that
reach the wire with the file they are meant to carry. The served file
holds a position-dependent pattern, so a repeat or a gap is reported at
its offset rather than as content that differs somewhere.
The first scenario holds the window still and must pass: it is the check
that the bench itself is sound, before the two moving-window scenarios
are believed.
uip_mss() is the limit on the next segment, not a record of the last
one: uIP recomputes it from the window the peer advertises in every
incoming segment, before the application is called. The ACK path
subtracted it from slen and added it to o_idx, and the retransmit path
handed it to uip_send(), so whenever the window moved between a segment
going out and its ACK coming back, the file being served lost or
repeated the difference. A window shrinking from 1460 to 600 between the
two repeats 860 bytes under fresh sequence numbers, which a browser
writes into the file; a window opening the same way skips 860.
Remember the length in tx_send() and use it in both places. The
retransmit path then repeats exactly the segment uIP still counts as
outstanding, which is what uip_connr->len makes it put on the wire.
uip_appdata is void *, so p - uip_appdata subtracts pointers of
different types. SDCC accepts it, C does not, and no host compiler will
build the file for a unit test. Cast to the type the byte count is meant
in; the generated firmware code is unchanged.
The vendor, model and serial strings are filtered while the EEPROM read
fills the buffers, so the page copies them out as they are. NUL still
ends a string, so a field shorter than its slot reads the same as before.
The three loops in send_status() become one call each. strcpy() cannot
return the length: rtl837x_common.h hides that prototype under
RTLP_HOST_TEST so host builds take the C library version, and a call
that adds its result to slen does not compile there. A small static
helper does the copy instead, and bank 1 drops by 96 bytes.
The console, POST /cmd and the saved config all go through the command
parser, so one filter there covers every way a name can be set. The
hostname already did this inline; port and VLAN names now do it too.
The SFP strings still need escaping on the way out: they come from the
module's EEPROM, not from a command.
A port named NAS"1 made status.json unparsable, so the page stopped
loading, and the name survives a reboot in the saved config. VLAN names
and the SFP strings have the same problem.
They now go through a helper that replaces ", \ and non-printable bytes
with a dot, the way the hostname is already sanitized on ingest. The
length does not change, so the size checks still hold.
The helper also covers the 0xa0 byte that send_sfp_info() skipped as a
special case, so that check is gone.
Compiling these two files for the host turns up warnings that SDCC does
not print: four places mix & with | and two mix && with ||, and l2_delete
keeps a counter it never reads. The parentheses only say what the
compiler already does, so the generated code is unchanged.
counter_to_html() reads the SFRs directly for the zero test, which saves
14 bytes of bank 1.
page_impl.c and rtl837x_port.c are linked together over the simulated
engine, so /vlan.json, /vlanlist and /l2.json are checked against what
vlan_create, pvid and the L2 table hold, through the same bytes the switch
would. The L2 walk is driven the way the web page drives it, page after
page until an index repeats, which is also where the repeat of the first
entry is pinned down as the wrap marker the page relies on. The counter
test fails on the code before the previous commit.
send_status wrote the high and the low word of a packet counter one after
the other, each without its leading zeros. That reads fine until a port
passes four billion packets; from then on a low word of 5 prints as "0x15"
next to a high word of 1, and the rates the page derives from the
difference between two readings jump around. send_counters already padded
the low word, so both now share one helper that pads it only when the high
word is set, which also drops the leading "0" the counters page used to
print in front of every small value.
The switch is reached through four register functions and the SFR_DATA
registers, so a flat register file behind them is enough to run the table
code on the host. A few addresses are live: writing TBL_CTRL with EXECUTE
performs the VLAN or L2 operation at once and clears the bit, STAT_GET
fetches a counter, L2_TBL_FLUSH_CTRL drops entries. Nothing ever reports
busy, so a polling loop runs once and the tests say nothing about what
happens when hardware stalls; that question was settled elsewhere.
The header states the VLAN and L2 entry layouts on its own, so a test can
hold what rtl837x_port.c writes against a second reading of the same bits
rather than against itself. The first suite does that for the VLAN entry,
the PVID register two ports share, the static multicast and management
entries, the per-port flush and the trunk registers. Two stub headers stand
in for the ones a firmware build generates, so the harness needs no SDCC
build first.
Two things kept every register-driven module out of the host harness. The
SFR keywords were unknown, so rtl837x_sfr.h did not compile at all, and once
it did, each translation unit would have defined its own copy of the
registers. They map to extern declarations now; a mock emits the storage
once by re-including the header with the keywords redefined.
The other was memset. rtl837x_common.h hides the firmware's own prototypes
under RTLP_HOST_TEST so host builds use the C library, but nothing declared
the library versions, and the modules do call them. The shim pulls in
string.h ahead of everything, where nothing can clash with it.
The messages said Error: themselves, or usage:, or nothing at all.
cmd_error() prints the prefix now, so every rejected command answers the
same way and the strings only carry what is specific to them.
Two messages that started with Error or refusing are reworded so the
prefix does not read twice. The syslog usage text becomes one string
instead of three calls.
The session cookie carried neither Expires nor Max-Age, so browsers that
clean up session cookies aggressively (LibreWolf, for one) may drop it
while the session is still valid. Send Max-Age=session_timeout so the
declared lifetime matches the timeout already enforced by the firmware.
itoa16_html() only converted four digits, so extend it to five to print
timeouts up to 65535. That also fixes information.json, which used the
same helper and reported wrong values from 10000 s up.
Adds a numeric input next to the syslog settings to read and set the
session timeout without knowing the command. The current value is
reported in information.json, so the field also shows the default the
firmware was built with.
Costs 86 bytes of code (BANK1) and nothing in RAM.
run_cmd_body() answers POST /cmd with 400 when err_status is set, but
only the tokenizer set it. Every "Error:", "Invalid ..." and "Unknown
command" from the parsers went back as 200, so the web page reported the
command as applied, and save_cmd put the rejected line into the command
history, from where Save to flash wrote it into the startup config.
Set ERR_INVALID_ARGUMENT on every path that rejects a command: the err:
labels of the parsers, the parsers that print their own error, the
stp parser and the unknown command fallback. Warnings that still apply
the command, such as a full VLAN name table, are left alone.
Record a command in the history only when it was accepted, and let
execute_commands() report the first failure of a multi-line body, since
cmd_tokenize() clears err_status again for every following line.
Save to flash ran the stored config through the same filter as the
command log, so stored lines the page does not know were dropped. The
stored lines are now carried over as they are and only the log is
filtered.
ingress only changes the ports it lists, but the merge replaced every
stored ingress line. It now merges per port; "ingress t|u|a" still
replaces everything, and per-port settings an all-ports line already
overrode are not revived.
Write from the config editor no longer clears the command log or the
unsaved marker, since the edited text does not hold the changes made on
other pages; only Save, which merges them, clears the log.
The command log grows from 1 kB to 2 kB, which still fits the 2500 byte
output buffer, and send_cmd_log() stops at the end of that buffer.
The workflow only ran on push, so a pull request opened from a fork
never got a build, and neither did the host-side unit tests that run in
the same job.
handle_post() takes the request path from byte 6 of the segment it is
given. For the first segment of a POST that is the path, but for a later
segment of a multipart upload it is whatever part of the file happens to
sit there. The cmd and login handlers were matched before the multipart
state was checked, so a segment of a config or firmware upload with
"cmd " at that offset ran the rest of the segment as CLI commands, and
one with "login " there aborted the upload with 400.
Check for an upload in progress, and for new upload and config requests,
before looking at cmd and login. A new POST cannot match both sets of
words, so nothing changes for requests that are not uploads.
session_id is cleared at boot and only a successful login fills it in,
while the uptime counter and last_session_use both start at 0. For the
first SESSION_TIMEOUT seconds after a start, a request carrying an empty
"Cookie: session=" therefore passes is_word_x(session, session_id) and
is treated as logged in, which is enough for /cmd, /config and /upload.
Only look at the cookie once a session has been handed out.