The hongyavision HYWS-SGT0204S is sold as an unmanaged 4x2.5G + 2x10G SFP+
switch and carries the 2G5F4_10G2_V1.01 marking on the PCB. It is a sibling of
the KP-9000-6XH-X2 (2M-PCB43-V1.1), so machine/2G5F4_10G2_V1_01.c is that board
definition with these changes:
- The two SFP+ cages (physical ports 5 and 6) are wired the other way round:
physical 5 is on SDS1 with GPIO30/GPIO37, physical 6 on SDS0 with
GPIO50/GPIO10. Copper ports 1-4 match the KP-9000 layout.
- No reset button is fitted and the case has no opening for one, so reset_pin
is GPIO_NA. GPIO54, the reset pin on the KP-9000 layout, reads as permanently
pressed here.
- The board definition sets flash_sio, so the flash is read with single-IO: the
fitted 512 KB Bright Moon T25S40 cannot be read in DIO mode on this board, an
image that leaves DIO enabled does not come up at all, while the same image
with single-IO boots and runs normally (two units).
- The board is added to the machine_custom_init() group that sets
LED_GLB_IO_EN bit 6, otherwise the RTL837x "solid" conditions (LINK/speed)
never drive the LEDs and the 2.5G LED glows faintly at 100M/1000M.
flash_sio is a new field of struct machine that rtlplayground.c hands to
flash_init(); only this board sets it, every other machine keeps DIO. It costs
management-plane speed only, the ASIC keeps forwarding in hardware.
The stock firmware runs a factory test console on the serial header at 9600
baud, whose silkscreen labels are shifted by one pin.
Verified: warning-free build, `make machine_check` passes for every target, the
host tests pass, and a control build of this target without the LED hook differs
from the KP-9000-6XH_X2_V1_1 image in 44 bytes: all inside the machine
description (including flash_sio) and the image CRC16, nothing else in the
firmware moved. On the board the single-IO image boots and runs on two units;
port order, SFP cages and LED behaviour come from the machine definition
verified on this board earlier.
Measured against the generic leds_setup() output on the board: eight of
the 21 stock values are identical to what leds_setup() computes from
the machine's led_mux table, and eight more revert to the generic
values with no change in LED behaviour in any tested link state (copper
2.5G, SFP 2.5G, SFP 10G). Keep the five with a measurable effect: 6528
selects blue over green at 10G, 6540/6548 carry the SFP and copper LED
set behaviour, 65dc enables the LED outputs, and PIN_MUX_0 routes the
blue pin.
Verified from a clean boot on a SWTG018AS-V2.1.0 board: copper solid
green with activity blink at 2.5G on two ports, SFP green at 2.5G,
SFP blue at 10G, LEDs off on link down.
machine_custom_init() runs once at boot, but its code and any tables it
uses were compiled into machine.c and so into the common bank. On the
SWTG018AS-V2.1.0 variant, whose init carries a 21-entry LED register
table, that overflows bank 0 by 0x66 bytes and main no longer links for
MACHINE_PCB_SWTG018AS_V2_1_0; any machine whose init grows can hit the
same wall. SDCC segment pragmas apply file-wide, so the hooks move to a
new machine_init.c compiled into BANK2, and the prototype becomes
banked. machine_check also compiles the new file per machine so the
hooks keep CI syntax coverage.