The hardware bitmask format encodes both "untagged members" and
"non-members" in the upper 10 bits (per doc/vlan.md). The existing
fetchVLAN() correctly masks this with the membership bitmask before
display, but loadVlanTable() did not, causing non-member ports to
appear in the Untagged Ports column.
Tested on KeepLiNK KP-9000-6XH-X.
Below the configuration form, a new table lists all configured VLANs
with their port memberships: Member, Tagged, Untagged, and PVID
columns. Port ranges are formatted compactly (e.g. "1-2,5").
Port-to-bit mapping uses the existing physToLogPort[] array populated
by /status.json, so the table is consistent with the icon view in
fetchVLAN() and works on any supported machine.
Each row has a delete button that sends "vlan N d" via /cmd, with
a confirmation dialog. VLAN 1 cannot be deleted (no button shown).
Table and dropdown both refresh automatically after Update/Create
and after delete via a new refreshVlanViews() helper.
The N+1 request pattern (1x /vlanlist + Nx /vlan.json) keeps the
backend simple and avoids buffer overflow risks for systems with
many VLANs. For typical configurations (<50 VLANs), page load
remains under one second.
A new <select> element above the VLAN ID input lets users pick an
existing VLAN by name instead of typing the ID. Options are loaded
from /vlanlist on page load and re-loaded after successful
Update/Create operations.
Selection triggers the existing fetchVLAN() flow.
Falls back gracefully if /vlanlist returns an empty list or fails:
the dropdown is hidden and the existing ID input remains functional.
When device has no LOS pin and module has no extended status, the
RX LOS value will not be shown. When both are present, the equality
check is performed. When only one is present, the present value
will be shown.
json from the switch, will still contain the field, but can be
null for when pin is not available.
The state of the SFP module is being already send in status.json,
but was not parsed via Web UI. When debuging SFP LOS/Signal detection
it is usefull to see what module is reporting back.
Extended the SFP mouse-over information with:
- RX LOS as reported in 0x02 bit of register 238
- External TX Disabled from 0x80 bit of register 238
- TX fault from 0x04 of the same register
- The last state of RX LOS pin (available also when there is no 0x40
option on the module)
This should help identify missing/incorrect setup of TX disabled pin.
I noticed that entering some vlan config, clicking "Update/Create", then
clicking "Get Configuration" resulted in Tagged/Untagged/PVID displaying
completely wrong data. It looks like the parisng in fetchVLAN() in
vlan.js was just completely disconnected from the layout of the
registers read by vlan_get() in rtl837x_port.c. Who knows how that
happened.
1. Fix fetchVLAN() member/untag parsing: the old code read bits [9:0]
as untagged and bits [10:19] as tagged, but the VLAN table register
layout is members in [9:0] and untag in [19:10]. Now correctly
derives tagged (member && !untag) and untagged (member && untag).
2. Add PVID to vlan.json response: PVID is stored per-port in separate
PVID registers (RTL837x_PVID_BASE_REG), not in the VLAN table entry.
The old code nonsensically tried to read it from bits [20:29] of the
VLAN table. Add port_pvid_get() and build a pvid bitmask in
send_vlan() so the JS can parse it correctly.
3. Remove auto-PVID logic from setC(): setC() is called by fetchVLAN()
while it's loading existing config, and so this logic mangled the
display of the existing config. Also, it doesn't make sense to
auto-set the PVID for tagged members (PVID relates to untagged
ingress.)