I noticed that entering some vlan config, clicking "Update/Create", then
clicking "Get Configuration" resulted in Tagged/Untagged/PVID displaying
completely wrong data. It looks like the parisng in fetchVLAN() in
vlan.js was just completely disconnected from the layout of the
registers read by vlan_get() in rtl837x_port.c. Who knows how that
happened.
1. Fix fetchVLAN() member/untag parsing: the old code read bits [9:0]
as untagged and bits [10:19] as tagged, but the VLAN table register
layout is members in [9:0] and untag in [19:10]. Now correctly
derives tagged (member && !untag) and untagged (member && untag).
2. Add PVID to vlan.json response: PVID is stored per-port in separate
PVID registers (RTL837x_PVID_BASE_REG), not in the VLAN table entry.
The old code nonsensically tried to read it from bits [20:29] of the
VLAN table. Add port_pvid_get() and build a pvid bitmask in
send_vlan() so the JS can parse it correctly.
3. Remove auto-PVID logic from setC(): setC() is called by fetchVLAN()
while it's loading existing config, and so this logic mangled the
display of the existing config. Also, it doesn't make sense to
auto-set the PVID for tagged members (PVID relates to untagged
ingress.)
This reduces the number of .js which are pulled by the browser
when loading a http page, which should reduce the loading time.
Also prepare for device-dependent logical to physical port
mappings.
flash_read_bulk() is kind of a printf function. But did not work as well.
flash_read_bulk() was used in the http generation so this needed to be changed as well.
For the website we decided that we are going to use CSR(Client Side Rendering).
So every HTML and JS files are now static.
Variables are fetched via json calls and output is render on the client side.
Also usefull for the future when we want a REST like API.
execute_config() was also using flash_read_bulk().
This have been replaced with flash_read_bulk() and parsing the flash_buf buffer.