Implements the standard 802.1D-2004/802.1w configuration surface:
Bridge: priority (0-15 x4096), hello time, max age, forward delay,
force-version (RSTP v2 / STP-compatible v0 Config BPDUs), tx hold
count (per-port per-second BPDU budget).
Per port: enable, admin edge (forwarding immediately - no listen gap),
auto edge (forwarding after 3 s of BPDU silence; DEFAULT, so
host-facing ports no longer take the full forward delay),
path cost (0=auto/20000), port priority, BPDU guard (port disabled
on BPDU receipt), root guard (never accept a better root on the
port), BPDU filter (no BPDUs in or out).
Engine additions: root max-age expiry (reclaim the tree when the root goes
silent), root path cost accounting (rx cost + root-port cost, advertised in
our BPDUs), loop detection (our own BPDU coming back blocks the port for a
listen period), topology-change counter, approximated per-port roles
(Root/Designated/Alternate) for diagnostics.
CLI: "stp prio|hello|maxage|fwd|txhold|version ..." and
"stp port <n> on|off|edge|cost|prio|guard|filter ..." (stp_parse, delegated
from cmd_parser); all forms accepted by the startup-config validator so the
whole configuration persists. /stp.json now reports config + status; the
Spanning Tree page exposes everything with immediate-apply controls and live
state/role columns (edit-in-flight guard against the 2 s refresh).
8051 memory: the module moves to code BANK2; internal-RAM pressure from
cross-bank calls resolved by xdata loop iterators/scratch, __reentrant on
the small helpers, and moving httpd's header-pointer globals to xdata.
Verified on hardware (SWTGW218AS): defaults land per standard; priority and
hello change live; admin-edge ports (the LACP bond uplinks) keep the LAN at
0% loss THROUGH "stp on"; auto-edge ports forward after 3 s; a port that
heard real BPDUs (a VM bridge behind physical port 6) correctly declined
auto-edge, sat out the full listen period and became Designated; tc counts
promotions; we win the root election at priority 16384 vs 32768.
(cherry picked from commit 09a34dc6acdc81ab9cab0727d2f4a59c68131a3e)
Add a Spanning Tree page: an on/off toggle driving the existing "stp"
command over /cmd, and a live status section fed by a new /stp.json
endpoint - the elected root bridge (priority + MAC), our path cost,
whether we are the root, and the per-port STP state read live from the
ASIC's MSTP register (same 2-bit encoding stp_setup() writes). Ports are
reported by their physical numbers.
Recovered-from: 3132319, 9365c86
Root cause of the "browser login always bounces back with Wrong password!
while curl works": scan_header() read the session id from a fixed offset
into the Cookie header (p + 17), assuming "session=" is the first and only
cookie. Browsers keep stale cookies for a long time - e.g. an "admin" cookie
left over from this switch's VENDOR firmware - so the header can arrive as
"Cookie: admin=..; session=..", the fixed offset then points into the admin
value, authentication silently fails and every page bounces to login although
the password had been accepted. curl sends only "session=", which is why
command-line tests passed while a real browser (with that stale cookie) failed.
- scan_header(): scan the Cookie header for the actual "session=" key
(matched as "session" - is_word() requires a separator after the pattern
and '=' is on its list, the first value byte is not).
- is_word_x(): accept ';' as a terminating separator so the session value
also matches when it is not the last cookie in the header.
Verified on hardware end-to-end in a real browser WITH the stale "admin"
cookie present: login -> index.html, all pages and JSON endpoints work.
Real root cause of the "web login fails from a browser but works from curl":
the uIP httpd is built with UIP_CONF_MAX_CONNECTIONS = 1 and uses global
response state (outbuf/slen/session), i.e. it serves exactly one TCP connection
at a time and closes it after each response - but never advertises that via
the Connection header. A browser's HTTP/1.1 client therefore assumes the
connection may be persistent and can park it in its keep-alive pool for reuse;
a later request sent on that pooled connection hits one the server has already
closed, and a POST (unlike a GET) is never retried by the browser, so it can
be silently lost this way.
This adds "Connection: close" to every response so the browser does not pool
and reuse a connection the server is about to drop. On its own this did not
fully explain the reported login failures - the actual authentication bug is
fixed in the next commit (the Cookie header parsed at a fixed offset) - but it
is correct behaviour for a server that only ever handles one connection, and
removes one source of dropped requests.
Two hygiene fixes for the web UI, prompted by a login that appeared to fail
under privacy shields (Brave Shields / NoScript-family extensions):
- httpd: replace the partial "style-src 'self' 'unsafe-inline'" CSP with a
complete, first-party policy (default-src 'self'; script-src 'self'
'unsafe-inline'; style-src 'self' 'unsafe-inline'; img-src 'self' data:;
connect-src 'self'; form-action 'self'). Everything the UI needs is
same-origin; the explicit policy stops shields injecting their own
restrictive report-only probes (the noisy script-src-elem 'none' console
spam) and passes a strict-CSP audit. Verified: no CSP violations in-browser.
- login.html: add autocomplete="current-password" so password managers
recognise the field (they showed "unknown password" without it).
NOTE: these do NOT bypass a browser's LAN-device protection (NoScript "lan" /
Brave Shields), which strips the POST body of requests to a LAN address and is
why the login can fail in-browser while the same credentials work over curl.
That is a deliberate browser security feature; the user must allow the site in
their shields to log in. The backend password (default 1234) is unchanged and
correct.
On a QSFPTEK QT-SFP+-T (RTL8261C) 10GBase-T module, the diag type field
(92) comes back as 0x00, but there's actually some statistics available
like temperature. Other metrics may be hard-coded values.
Add a basic struct that allows matching on vendor and/or model, using a
bitfield to allow multiple quirks for a given SFP module. Only
SFP_QUIRK_DDM is implemented.
For modules matching SFP_QUIRK_DDM, attempt an I2C read of the MSB of
module voltage during probe if DDM is "unsupported" - if it's not 0xff,
override the reported options so we can pull the diagnostic data.
To allow simpler comparisons, convert the ASCII fields (vendor,
model, serial) from space-padded to standard NULL-terminated strings.
strcmp() is moved from httpd.c to rtlplayground.c alongside other string
functions and shared between them.
The __reentrant keyword is used for the new functions to avoid using up
additional OSEG space. This allocates the variables on the stack, which
is OK for this particular code path.
The JSON assembly in send_status() is slightly modified to treat the
sfp_module_* data as standard NULL-terminated strings, and a repeated
subtraction was moved into a uint8_t to declutter the code.
- itoa16_html: add comment that the function is sufficient for VLAN
IDs (<=4094); generalization not needed.
- send_vlanlist: replace post-write bounds check with a pre-write
guard using worst-case entry size (138 bytes + 1 for closing
bracket). Old comment claimed ~45 bytes per entry, which only
held for short names. With a 117-char name (the actual bound from
CMD_BUF_SIZE) entries can reach 138 bytes, and the post-check
would not have prevented an overflow.
- Document the 0x02 check in sfr_data[0] as the VLAN table entry
valid flag.
Returns a JSON array of all configured VLANs with their IDs and names,
e.g. [{"id":1,"name":""},{"id":20,"name":"IoT"}].
The endpoint iterates VLAN IDs 1..4094 and filters by the validity bit
in sfr_data[0] (0x02), following the same pattern as vlan_create() and
vlan_setup() in rtl837x_port.c.
Also adds a small itoa16_html() helper for emitting decimal numbers
up to 4 digits (analogous to the existing 8-bit itoa_html()), used
for VLAN IDs which can reach 4094. Response builder uses the existing
vlan_name() helper for the name lookup, consistent with send_vlan().
Buffer overflow is prevented by breaking out of the iteration loop at
TCP_OUTBUF_SIZE - 60.
This endpoint is the foundation for upcoming UI improvements
(VLAN selector dropdown and overview table).
With content_type = "application/x-www-form-urlencoded", "+" means space.
This case was not handled.
Also refactor the code to make a loop to process the hex digits.
Chrome sends upload requests using POST with multipart/form-data
content type in multiple packets for the header part of the form-data.
Introduce a TSTATE_MULTIPART for the httpd server states that denotes
that so far only a part of the multipart header has been transmitted.
Once the full header has been transmitted, we change to TSTATE_POST
as for Firefox which sends all the multipart header in one piece.
The main further change required then is to make sure that the parsing
of the initial part of the multipart request is only parsed once and initially
to distinguish between configuration and firmware uploads.
While the current implementation works for what it is actually used, it
is broken when trying to do larger transfers.
The length field in the control register has a size of 4 bits. In every
transfer, length+1 bytes are read. Thus, each transfer is limited to a
maximum of 16 bytes. Add a check for the length, and write the correct
value to the register.
Also update the loop in "sfp_send_data" to properly increment the output
register. Remove the unused special case for a length of 128 bytes.
When device has no LOS pin and module has no extended status, the
RX LOS value will not be shown. When both are present, the equality
check is performed. When only one is present, the present value
will be shown.
json from the switch, will still contain the field, but can be
null for when pin is not available.
The state of the SFP module is being already send in status.json,
but was not parsed via Web UI. When debuging SFP LOS/Signal detection
it is usefull to see what module is reporting back.
Extended the SFP mouse-over information with:
- RX LOS as reported in 0x02 bit of register 238
- External TX Disabled from 0x80 bit of register 238
- TX fault from 0x04 of the same register
- The last state of RX LOS pin (available also when there is no 0x40
option on the module)
This should help identify missing/incorrect setup of TX disabled pin.
I noticed that entering some vlan config, clicking "Update/Create", then
clicking "Get Configuration" resulted in Tagged/Untagged/PVID displaying
completely wrong data. It looks like the parisng in fetchVLAN() in
vlan.js was just completely disconnected from the layout of the
registers read by vlan_get() in rtl837x_port.c. Who knows how that
happened.
1. Fix fetchVLAN() member/untag parsing: the old code read bits [9:0]
as untagged and bits [10:19] as tagged, but the VLAN table register
layout is members in [9:0] and untag in [19:10]. Now correctly
derives tagged (member && !untag) and untagged (member && untag).
2. Add PVID to vlan.json response: PVID is stored per-port in separate
PVID registers (RTL837x_PVID_BASE_REG), not in the VLAN table entry.
The old code nonsensically tried to read it from bits [20:29] of the
VLAN table. Add port_pvid_get() and build a pvid bitmask in
send_vlan() so the JS can parse it correctly.
3. Remove auto-PVID logic from setC(): setC() is called by fetchVLAN()
while it's loading existing config, and so this logic mangled the
display of the existing config. Also, it doesn't make sense to
auto-set the PVID for tagged members (PVID relates to untagged
ingress.)