d00f 531bbbea5d stp: full RSTP configuration (bridge + per-port), CLI + GUI + persistence
Implements the standard 802.1D-2004/802.1w configuration surface:

Bridge:  priority (0-15 x4096), hello time, max age, forward delay,
         force-version (RSTP v2 / STP-compatible v0 Config BPDUs), tx hold
         count (per-port per-second BPDU budget).
Per port: enable, admin edge (forwarding immediately - no listen gap),
         auto edge (forwarding after 3 s of BPDU silence; DEFAULT, so
         host-facing ports no longer take the full forward delay),
         path cost (0=auto/20000), port priority, BPDU guard (port disabled
         on BPDU receipt), root guard (never accept a better root on the
         port), BPDU filter (no BPDUs in or out).

Engine additions: root max-age expiry (reclaim the tree when the root goes
silent), root path cost accounting (rx cost + root-port cost, advertised in
our BPDUs), loop detection (our own BPDU coming back blocks the port for a
listen period), topology-change counter, approximated per-port roles
(Root/Designated/Alternate) for diagnostics.

CLI: "stp prio|hello|maxage|fwd|txhold|version ..." and
"stp port <n> on|off|edge|cost|prio|guard|filter ..." (stp_parse, delegated
from cmd_parser); all forms accepted by the startup-config validator so the
whole configuration persists. /stp.json now reports config + status; the
Spanning Tree page exposes everything with immediate-apply controls and live
state/role columns (edit-in-flight guard against the 2 s refresh).

8051 memory: the module moves to code BANK2; internal-RAM pressure from
cross-bank calls resolved by xdata loop iterators/scratch, __reentrant on
the small helpers, and moving httpd's header-pointer globals to xdata.

Verified on hardware (SWTGW218AS): defaults land per standard; priority and
hello change live; admin-edge ports (the LACP bond uplinks) keep the LAN at
0% loss THROUGH "stp on"; auto-edge ports forward after 3 s; a port that
heard real BPDUs (a VM bridge behind physical port 6) correctly declined
auto-edge, sat out the full listen period and became Designated; tc counts
promotions; we win the root election at priority 16384 vs 32768.

(cherry picked from commit 09a34dc6acdc81ab9cab0727d2f4a59c68131a3e)
2026-08-04 03:25:10 +02:00
Erdnusschokolade 4eaf16f96d Drop dead exact-match check in vlan delete filter
A bare "vlan N" line never matches conf_cmds (a VLAN entry always carries
a member port or the mgmt/name keyword), so it is never stored. The
c !== "vlan N" comparison could therefore never match an entry; the
startsWith(prefix) check alone covers all stored vlan lines.
2026-06-20 08:13:43 +02:00
Erdnusschokolade 718745e7b5 Reduce stale management VLAN entries on config save
The firmware has a single management VLAN (one management_vlan variable),
so a stored config should never carry more than one "vlan N mgmt" line.
When parsing a mgmt command, drop any previously stored mgmt entry so
repeatedly changing the management VLAN no longer accumulates stale lines.
2026-06-20 08:00:54 +02:00
Erdnusschokolade 06ee1ce38e Persist port speed settings in config parser
parseConf() only recognized "port N name" in conf_cmds, so "port N <speed>"
lines were treated as unknown commands and dropped on save - configured port
speeds never persisted.

Add the speed command (incl. optional half/full duplex suffix) to conf_cmds,
add a "port N" entry to conf_overwrite so re-saving a speed replaces the
previous value, and guard the per-port name entry so changing a port's speed
no longer wipes its configured name.
2026-06-18 14:49:56 +02:00
Erdnusschokolade 592b903305 Fix conf_overwrite filter removing vlan mgmt entries
The vlan/mgmt lookahead split (commit dcc60c3) correctly separated the
patterns so that `vlan N mgmt` and `vlan N <members>` match different
conf_overwrite entries. But the filter that applies the overwrite still
used `item.startsWith(matchStr + " ")` with matchStr = "vlan N", which
also matches "vlan N mgmt" — so the management entry was removed whenever
the VLAN's membership definition was re-saved.

Example: with both `vlan 44 management 2t 4t 5 6t` and `vlan 44 mgmt`
in the config, changing the membership dropped `vlan 44 mgmt` entirely.

Added a `!item.endsWith(" mgmt")` guard so management entries survive the
filter. No reordering is needed: `vlan N mgmt` only sets the global
management_vlan variable (cmd_parser.c) and does not depend on the VLAN
table entry existing, so its position in the config is irrelevant.
2026-06-02 22:52:06 +02:00
Erdnusschokolade dcc60c3824 Fix conf_overwrite vlan/mgmt conflict
The pattern /^vlan\s+\d{1,4}\b/ matched both VLAN membership entries
(vlan N <ports>) and management entries (vlan N mgmt), causing them
to overwrite each other in configuration[]. When saving, whichever
form came last in the cmd_log would dedupe the other out of the
final config — resulting in either lost membership or a stale mgmt
setting.

Split into two patterns using negative lookahead:
- /^vlan\s+\d{1,4}\s+mgmt$/      matches only mgmt entries
- /^vlan\s+\d{1,4}(?!\s+mgmt\b)/  matches everything else

Both dedup independently. Discovered via hardware test on 6XH-X
where 'vlan 44 mgmt' silently dropped 'vlan 44 management 2t 5u'
from saved config, locking out web UI on next boot.
2026-05-24 11:26:04 +02:00
Erdnusschokolade caad366b3b Fix config persistence: missing commands, delete handling, multipart
Multiple related bugs in the Save-to-Flash path:

1. Multipart upload was missing the required filename argument,
   causing the backend parser to fail. Added 'config.txt' to the
   form.append call. This was likely the primary reason Save-to-Flash
   was unreliable.

2. Web UI was not pausing its polling interval during flash write,
   causing CPU contention and intermittent crashes. Added isSaving
   lock and clearInterval before sendConfig.

3. conf_cmds whitelist was incomplete. Added: syslog, passwd, pvid,
   ingress, port name, lag, laghash, isolate, stp, igmp, mtu, bw,
   vlan N mgmt, vlan N d.

4. VLAN regex blocked named VLANs. New pattern allows optional name
   (starts with letter, matching CLI parser semantics).

5. vlan N d (delete) was not persisted. parseConf now removes the
   matching vlan N ... entry from configuration[] when seeing a
   delete command, without storing the delete itself. Result: the
   saved config describes the end state.

6. configuration[] was not cleared between flashSave invocations,
   leading to stale entries from prior interactions.

7. conf_overwrite boundary fix: 'pvid 1' no longer matches 'pvid 10'
   etc. Added trailing space in startsWith check.

8. All conf_cmds patterns now anchored with ^...$ for full-line
   match. parseConf normalizes whitespace before testing.

9. Port range widened to \d{1,2} so ports 11+ are accepted.

Structural fixes (1, 2, 6, 7, 8) ported from mcaptur's closed PR #219;
remaining fixes (3, 4, 5, 9) and overall regex strategy are new.
2026-05-24 11:26:04 +02:00
chriz b5c249995f Add startup config editor. 2026-01-26 20:40:30 +01:00
logicog 00a415c755 Add filtering logic for configuration commands 2025-11-29 12:44:23 +01:00
logicog ba9bc2e845 Initial web-files for system settings and configuration management 2025-11-29 12:44:23 +01:00