When device has no LOS pin and module has no extended status, the
RX LOS value will not be shown. When both are present, the equality
check is performed. When only one is present, the present value
will be shown.
json from the switch, will still contain the field, but can be
null for when pin is not available.
The state of the SFP module is being already send in status.json,
but was not parsed via Web UI. When debuging SFP LOS/Signal detection
it is usefull to see what module is reporting back.
Extended the SFP mouse-over information with:
- RX LOS as reported in 0x02 bit of register 238
- External TX Disabled from 0x80 bit of register 238
- TX fault from 0x04 of the same register
- The last state of RX LOS pin (available also when there is no 0x40
option on the module)
This should help identify missing/incorrect setup of TX disabled pin.
This reduces the number of .js which are pulled by the browser
when loading a http page, which should reduce the loading time.
Also prepare for device-dependent logical to physical port
mappings.