# LACP (Link Aggregation Control Protocol, IEEE 802.3ad)
|
# LACP (Link Aggregation Control Protocol, IEEE 802.3ad)
|
||||||
|
|
||||||
A static link aggregation group works only if both ends agree about it in
|
A static link aggregation group works only if both ends are configured for the
|
||||||
advance. Nothing checks that they do: cable a member to the wrong neighbour and
|
same links, and nothing checks that they are. LACP lets the two ends agree on
|
||||||
the group keeps hashing frames onto a link that goes somewhere else. LACP is the
|
which links reach the same partner, aggregates only those, and takes a link out
|
||||||
protocol that makes the two ends agree, and keeps agreeing — it discovers which
|
of the group when the partner stops answering.
|
||||||
links reach the same partner, aggregates only those, and drops a link out of the
|
|
||||||
group when the partner stops answering.
|
|
||||||
|
|
||||||
The switch runs LACP in software on the 8051. Frames are the Slow Protocols
|
The switch runs LACP in software on the 8051. LACP frames belong to the Slow
|
||||||
group: destination `01:80:C2:00:00:02`, ethertype `0x8809`, subtype 1. The
|
Protocols, with destination `01:80:C2:00:00:02` and ethertype `0x8809`; the
|
||||||
implementation covers the parts that decide whether an aggregate forms:
|
subtype of LACP frames is 1. The implementation has the Receive, Selection and
|
||||||
the Receive machine and the Selection and Mux machines of 802.3ad clause 43,
|
Mux machines of 802.3ad clause 43 and does not aggregate links whose partners
|
||||||
`recordPDU` and `update_NTT`, and the mis-cabling protection that refuses to
|
differ. Up to `LACP_NUM_LAGS` (4) groups can run LACP; the others stay static.
|
||||||
aggregate links whose partners differ. It does not implement the Churn Detection
|
|
||||||
machines or the Marker protocol, and the Mux machine is the coupled variant, so
|
|
||||||
collecting and distributing are enabled together rather than in sequence.
|
|
||||||
|
|
||||||
Up to `LACP_NUM_LAGS` (4) groups can be placed under LACP; the rest stay static.
|
|
||||||
|
|
||||||
## Getting the frames to the CPU
|
## Getting the frames to the CPU
|
||||||
|
|
||||||
Reserved multicast addresses are handled by the RMA block before the L2 lookup
|
While LACP runs, the reserved multicast action for `01:80:C2:00:00:02` is
|
||||||
happens. Each address has its own register and the action field sits in bits
|
*trap*, the same mechanism STP uses for its BPDUs, see [stp.md](stp.md). A
|
||||||
[5:4]: 0 forward, 1 trap to CPU, 2 drop, 3 forward excluding the CPU. The
|
trapped LACPDU has no VLAN tag after the RTL tag, and `TRAP_RX_BODY()` gives the
|
||||||
registers are packed and consecutive by *entry* rather than by address byte, so
|
offset of the LACPDU in the received frame. When the last group leaves LACP,
|
||||||
the step of 4 counts entries, not bytes of the address: `...:00` sits at
|
the action goes back to *drop*.
|
||||||
`0x4ecc` and `...:02` at `0x4ed4`, but `...:08` sits at `0x4ee0`.
|
|
||||||
|
|
||||||
```
|
|
||||||
#define RTL837X_RMA0_CONF 0x4ecc /* 01:80:C2:00:00:00, entry 0 */
|
|
||||||
#define RTL837X_RMA2_CONF 0x4ed4 /* 01:80:C2:00:00:02, Slow Protocols */
|
|
||||||
#define RTL837X_RMA_ACT_MASK 0x30
|
|
||||||
#define RTL837X_RMA_ACT_TRAP 0x10
|
|
||||||
#define RTL837X_RMA_ACT_DROP 0x20
|
|
||||||
```
|
|
||||||
|
|
||||||
The engine puts this address on *trap* while it runs. A trap takes the frame
|
|
||||||
out of the forwarding path and hands it to the port named in `EXT_CPU_CTRL`
|
|
||||||
(`0x6724`), whose reset value names no port at all: the destination is meant to
|
|
||||||
be an *external* CPU on a physical port, which these boards do not have. That
|
|
||||||
is why the trap first looked like a dead end - the receive counters stayed
|
|
||||||
frozen while the partner kept sending, and the ingress discard counter grew
|
|
||||||
instead. `trap_init()` points the register at the CPU port once at startup, and
|
|
||||||
the same frames then arrive.
|
|
||||||
|
|
||||||
`FORWARD` reaches the CPU too, because the CPU port is in the forwarding
|
|
||||||
domain, but a forwarded frame is subject to the L2 lookup and on its own floods
|
|
||||||
to every other port in the VLAN. That leaks a neighbour's LACPDUs to hosts that
|
|
||||||
must not see them and, with two bonds on one switch, poisons both; a reserved
|
|
||||||
link-local group must not be forwarded at all. Containing it takes a static L2
|
|
||||||
multicast entry with a CPU-only member mask, and because lookups are IVL on
|
|
||||||
this chip, one entry per distinct pvid over all front panel ports - a VID 0
|
|
||||||
entry is never matched, and a port outside the LACP groups needs its pvid
|
|
||||||
covered as well, or a LACPDU arriving there misses the lookup and is flooded
|
|
||||||
through its VLAN.
|
|
||||||
|
|
||||||
The trap needs none of that and reaches further, because it acts on the address
|
|
||||||
before the VLAN lookup and before the ingress filters. An untagged LACPDU is
|
|
||||||
delivered on a port that admits tagged frames only, where a forwarded one is
|
|
||||||
dropped by the acceptable-frame-type filter; and it is delivered on a port STP
|
|
||||||
holds in blocking, so a group converges without waiting out the forward delay.
|
|
||||||
Both were measured against forward on the same ports of an SWTGW218AS.
|
|
||||||
|
|
||||||
A trapped frame arrives without the VLAN tag the hardware inserts into a
|
|
||||||
forwarded one, so the LACPDU body sits four bytes earlier. `TRAP_RX_BODY()`
|
|
||||||
gives the offset of the body for either form, and `lacp_in()` reads the PDU
|
|
||||||
from there.
|
|
||||||
|
|
||||||
Neighbouring addresses in the same block still differ in other respects -
|
|
||||||
`...:00` is exempt from the ingress STP-state check and `...:02` is not, which
|
|
||||||
the trap makes moot only because it acts before that check - so measure before
|
|
||||||
carrying a conclusion about one of them across to another.
|
|
||||||
|
|
||||||
When LACP is switched off the action goes to `DROP`, which acts before the L2
|
|
||||||
lookup, so there is nothing to undo.
|
|
||||||
|
|
||||||
## What has to match across the members
|
## What has to match across the members
|
||||||
|
|
||||||
@@ -92,42 +36,30 @@ mismatch should be rejected or applied to the whole group.
|
|||||||
|
|
||||||
## Protocol timing
|
## Protocol timing
|
||||||
|
|
||||||
```
|
The timer values are in units of the LACP timer, which steps every four ticks
|
||||||
#define LACP_FAST_PERIODIC 0x0032 /* fast TX 1 s; partner expires at 3 s */
|
of the system clock, 50 times per second:
|
||||||
#define LACP_SLOW_PERIODIC 0x05dc /* slow TX 30 s; partner expires at 90 s */
|
|
||||||
#define LACP_SHORT_TIMEOUT 0x00c8 /* silent partner dropped after 4 s (802.3ad: 3 s) */
|
|
||||||
```
|
|
||||||
|
|
||||||
One unit is one step of the LACP timers, taken every four system ticks, so 50
|
| Constant | Value | Time |
|
||||||
per second whatever the pace of the main loop; 50 units came out as 1.00 s on
|
|----------------------|-------|------|
|
||||||
the wire in all 116 intervals of a two minute capture.
|
| `LACP_FAST_PERIODIC` | 50 | 1 s |
|
||||||
|
| `LACP_SLOW_PERIODIC` | 1500 | 30 s |
|
||||||
|
| `LACP_SHORT_TIMEOUT` | 200 | 4 s |
|
||||||
|
|
||||||
The two transmit periods are worth a word, because they are the one thing here
|
802.3ad specifies a fast periodic time of 1 s with a short timeout of 3 s, and a
|
||||||
that is not ours to choose freely. Our own timeouts only decide how patient we
|
slow periodic time of 30 s with a long timeout of 90 s. The switch transmits at
|
||||||
are with a partner that has gone quiet, and being slow there costs nobody
|
the rate the partner asks for with its TIMEOUT bit. Its own timeout is always
|
||||||
anything. The transmit period is the opposite: it decides when the *partner*
|
the short one, one second above the standard, so a partner that stops sending
|
||||||
gives up on us. 802.3ad pairs a 1 s fast period with a 3 s short timeout, and a
|
while its link stays up leaves the trunk after 4 s.
|
||||||
30 s slow period with a 90 s long timeout, and the ratio is the whole point.
|
|
||||||
|
|
||||||
Getting that wrong does not break the aggregate, which is what makes it easy to
|
The Partner block of a transmitted LACPDU repeats the partner's actor
|
||||||
miss. An earlier version of this code transmitted every 2 to 3 s while the
|
information as it was last received: system priority, system, key, port
|
||||||
partner was asking for the fast rate. The links still aggregated and still
|
priority, port and state. A Linux partner sets our SYNC only when this block
|
||||||
carried traffic, but every time a gap crossed 3 s the partner's receive machine
|
matches what it sent.
|
||||||
timed us out and recovered: 13 of its 93 LACPDUs came back carrying `EXPIRED`
|
|
||||||
and reporting our SYNC as cleared. Since a received actor state is recorded
|
|
||||||
verbatim as the partner state and sent back out, the flap was visible from both
|
|
||||||
ends, and the bond's churn machines never settled. With the periods above, the
|
|
||||||
same capture shows no expiry at all and both churn states read `none`.
|
|
||||||
|
|
||||||
Our own timeouts sit one period above the standard's 3 s and 90 s, which
|
|
||||||
absorbs a single lost LACPDU plus the tick jitter. A partner whose LACP has
|
|
||||||
stopped while its link stayed up is out of the trunk after that; anything
|
|
||||||
longer keeps hashing traffic onto a member that no longer agrees to carry it.
|
|
||||||
|
|
||||||
## LACP API
|
## LACP API
|
||||||
|
|
||||||
```
|
```
|
||||||
void lacp_init(void) __banked; /* boot init: clear per-LAG state */
|
void lacp_init(void) __banked;
|
||||||
void lacp_off(void) __banked;
|
void lacp_off(void) __banked;
|
||||||
void lacp_lag_set(uint8_t lag, __xdata uint16_t ports) __banked;
|
void lacp_lag_set(uint8_t lag, __xdata uint16_t ports) __banked;
|
||||||
void lacp_in(void) __banked;
|
void lacp_in(void) __banked;
|
||||||
@@ -193,35 +125,25 @@ On the switch, with those two ports as the group:
|
|||||||
lag 1 lacp 7 8
|
lag 1 lacp 7 8
|
||||||
```
|
```
|
||||||
|
|
||||||
`lacp show` should then give both ports an actor state of `0x3f`, which is
|
`lacp show` should then give both ports an actor state of `0x3f` (ACTIVITY,
|
||||||
ACTIVITY, TIMEOUT, AGGREGATION, SYNC, COLLECTING and DISTRIBUTING together, a
|
TIMEOUT, AGGREGATION, SYNC, COLLECTING and DISTRIBUTING), a partner state with
|
||||||
partner state with SYNC in it, and the partner's system MAC. `lag show` should
|
SYNC set, and the partner's system MAC. `lag show` lists the trunk members as
|
||||||
list both ports as trunk members, since that reads the hardware rather than the
|
programmed in the hardware and should show both ports.
|
||||||
protocol's opinion of itself.
|
|
||||||
|
|
||||||
The host's view is the one worth trusting, in `/proc/net/bonding/bond0`. Both
|
On the host, `/proc/net/bonding/bond0` should show the same `Aggregator ID` for
|
||||||
slaves want the **same `Aggregator ID`**; two different numbers mean the bond
|
both slaves; different IDs mean that each link is in a group of its own. Both
|
||||||
has not aggregated anything and each link is sitting in its own group, which
|
churn states should read `none`.
|
||||||
looks healthy at a glance and is not. Both churn states should read `none`.
|
|
||||||
`monitoring` that never settles is the signature of our transmit period being
|
|
||||||
too slow for the rate the partner asked for.
|
|
||||||
|
|
||||||
Three things are worth checking past convergence, because each of them has been
|
Further checks:
|
||||||
broken here at some point:
|
|
||||||
|
|
||||||
* `tcpdump -i enp1s0 ether proto 0x8809` on each slave should show the switch's
|
* `tcpdump -i enp1s0 ether proto 0x8809` on each slave shows the LACPDUs of the
|
||||||
LACPDUs and that slave's own, and never the other slave's. A sibling leak is
|
switch and of that slave, never those of the other slave.
|
||||||
what the trap prevents: the PDU never enters the forwarding path at all.
|
* The host log has no `illegal loopback`.
|
||||||
* No `illegal loopback` in the host's log.
|
* The three reserved bytes after the actor state in a LACPDU from the switch
|
||||||
* In a hex dump of a frame from the switch, the three reserved bytes after the
|
are zero.
|
||||||
actor state should be zero. They used to carry whatever the transmit buffer
|
|
||||||
held from the previous frame.
|
|
||||||
|
|
||||||
Pulling one slave down and putting it back is the cheapest failure test. The
|
When one slave goes down, the group narrows to the remaining member, and the
|
||||||
group narrows to the surviving member and comes back within tens of seconds,
|
slave rejoins after it comes back.
|
||||||
and traffic across the transition loses a few percent at the edges rather than
|
|
||||||
half of everything, which is what it would lose if the ASIC kept hashing onto
|
|
||||||
the dead member.
|
|
||||||
|
|
||||||
## Known limits
|
## Known limits
|
||||||
|
|
||||||
|
|||||||
@@ -227,3 +227,7 @@ iperf Done.
|
|||||||
```
|
```
|
||||||
As you can see, the total throughput was 4.71 GBit/sec which is close to the
|
As you can see, the total throughput was 4.71 GBit/sec which is close to the
|
||||||
maximum possible with a single 5GBit link.
|
maximum possible with a single 5GBit link.
|
||||||
|
|
||||||
|
## LACP
|
||||||
|
|
||||||
|
Dynamic aggregation with LACP is described in [lacp.md](lacp.md).
|
||||||