Fix links in SFP doc
This commit is contained in:
+4
-4
@@ -6,8 +6,8 @@ implemented due to the lack of suitable modules.
|
|||||||
|
|
||||||
When a module is inserted, it directly connects to GPIO, I2C and RX/TX data lines of
|
When a module is inserted, it directly connects to GPIO, I2C and RX/TX data lines of
|
||||||
the SoC. An example schematics can be found here:
|
the SoC. An example schematics can be found here:
|
||||||
(SFP Module Schematics)[https://sfp.by/source/manual/SCP6F44-GL-BWE.pdf]. Another
|
[SFP Module Schematics](https://sfp.by/source/manual/SCP6F44-GL-BWE.pdf). Another
|
||||||
resources is (here)[https://www.sfptransceiver.com/product_pdf/SFP/SFP%20Design%20Guide.pdf].
|
resources is [here](https://www.sfptransceiver.com/product_pdf/SFP/SFP%20Design%20Guide.pdf).
|
||||||
The SoC
|
The SoC
|
||||||
detects the insertion because the MOD-DEF0 line is pulled low by the module. The
|
detects the insertion because the MOD-DEF0 line is pulled low by the module. The
|
||||||
corresponding bit in RTL837X_REG_GPIO_B or RTL837X_REG_GPIO_C will transition from
|
corresponding bit in RTL837X_REG_GPIO_B or RTL837X_REG_GPIO_C will transition from
|
||||||
@@ -57,7 +57,7 @@ uint8_t sfp_read_reg(uint8_t slot, uint8_t reg)
|
|||||||
```
|
```
|
||||||
|
|
||||||
The description of the data stored in the EEPROM can be found in the
|
The description of the data stored in the EEPROM can be found in the
|
||||||
(SFF-8472 standard)[https://members.snia.org/document/dl/25916]
|
[SFF-8472 standard](https://members.snia.org/document/dl/25916)
|
||||||
The most relevant is byte 12 (0x0c), which gives the signalling rate of the module in
|
The most relevant is byte 12 (0x0c), which gives the signalling rate of the module in
|
||||||
100MBit, including the 25% overhead for error correction. Currently the code looks like
|
100MBit, including the 25% overhead for error correction. Currently the code looks like
|
||||||
this:
|
this:
|
||||||
@@ -81,7 +81,7 @@ a 1000BX fiber module.
|
|||||||
|
|
||||||
In order to transmit data or receive data from the module, the SerDes of the SoC connected
|
In order to transmit data or receive data from the module, the SerDes of the SoC connected
|
||||||
to the module needs to e properly configured. As can be seen from the
|
to the module needs to e properly configured. As can be seen from the
|
||||||
(SFP Module Schematics)[https://sfp.by/source/manual/SCP6F44-GL-BWE.pdf], the Photo-transistor
|
[SFP Module Schematics](https://sfp.by/source/manual/SCP6F44-GL-BWE.pdf), the Photo-transistor
|
||||||
of the module is optimized by an amplifier and quantized to bits, which directly arrive
|
of the module is optimized by an amplifier and quantized to bits, which directly arrive
|
||||||
at the SoC in a differential pair. This data still has the 25% overhead of the error correction
|
at the SoC in a differential pair. This data still has the 25% overhead of the error correction
|
||||||
codes that were on the fiber. The switch needs to configure the SerDes correctl (sds_config())
|
codes that were on the fiber. The switch needs to configure the SerDes correctl (sds_config())
|
||||||
|
|||||||